Equipment Description: 180K NITROGEN PUMPING UNIT
General Information
The HPT (Hydraulic Power Technology) 180K nitrogen unit is designed to supply gaseous nitrogen at flow rates up to 180,000 SCFH (3000 SCFM) and pressures up to 10,000 psig. The minimum outlet gas temperature at full rate will not be lower than 70 degrees Fahrenheit. The energy required to vaporize the liquid nitrogen comes from two sources; engine heat recovery and hydraulic system heat recovery.
Specifications:
Unit Weight and Dimensions
Height | 102 in |
Length | 150 in |
Width | 96 in |
Dry Weight | 16,000 lb |
Wet Weight | 18,000 lb |
Capacities
Maximum pressure (LN2 Discharge) | 10,000 psig |
Maximum Flow Rate | 180,000 SCFH (3000 SCFM) |
Minimum Flow Rate | 400 SCFM |
Hydraulic reservoir | 96 Gallons |
Diesel fuel reservoir | 140 Gallons |
Pneumatic reservoir | 30 Gallons |